External Thermal Insulation Board

External Thermal Insulation Board External Thermal Insulation Board 1 External Thermal Insulation Board 2 External Thermal Insulation Board 3

External Thermal Insulation Board (FRB series) is designed for external insulation composite system and dry-hanging curtain wall thermal insulation system as a fire proof insulation material. With high compressive and tensile strength, excellent hydrophobic and moisture proof property, it can be applied on all kinds of solid wall substrate such as masonry and concrete, and both suitable for new/expansion project and retrofitting project of existing buildings/ When a fire breaks out, the product’s class-A non-combustibility and good anti-high temperature shrink can maintain the stability of the system structure.

Technical Specifications

Standard Specification

Product

FRB 75

FRB 100

FRB 150

Nominal Density, kg/ m³

≥140

≥140

≥150

Size(LxW), mm

1200x600

Thickness, mm

40~120

Other size or density may be available on request

Main Properties

Properties

FRB75

FRB100

FRB150

Unit

Standard

Compressive Strength (10%deformation)

≥40

≥50

≥60

kPa

GB/T 13480

EN 826

Tensile Strength

(perpendicular to surface)

≥7.5

≥10

≥15

kPa

JG149-2003 Annex D

EN 1607

Reaction to Fire

Class A

---

GB 8624-2006

EN 13501-1

Acidity Coefficient

≥1.8

≥1.8

≥1.8

---

GB/T 5480

Water Repellence

≥99

≥99

≥99

%

GB/T 10299

Water Vapor Absorption

≤1.0

≤1.0

≤1.0

wt%

BG/T 5480

ASTM C1104M

Short-term Water Absorption

(partial immersion,24h)

≤0.5

≤0.5

≤0.5

kg/m²

GB/T 25975-2010

Annex B EN1609

Long-term Water Absorption(partial immersion, 28d)

≤2.0

≤2.0

≤2.0

kg/m²

GB/T 25975-2010

ANNEX B EN 12087

Noise Reduction Coefficient(NRC)

≥0.6

≥0.6

≥0.6

---

GB/T 18696.1

ASTM C 423

Dimension Stability

≤1.0

≤1.0

≤1.0

%

GB/T 8811

EN 1604

Melting Point

≥1000

≥1000

≥1000

---

Thickness Deviation

±3

±3

±3

mm

GB/T 5480

EN 13162

Squareness

≤5

≤5

≤5

mm/m

GB/T 5480

EN 824

Flatness

≤5

≤5

≤5

mm

GB/T25975-2010

Annex B EN 825

Other properties meet GB/T 25975-2010 and 19686-2005’ requirements